PARITY=NotPresent, BREAK=NotPresent, FRAMING=NotPresent, OVERRUN=NotPresent
Error source. Write error field to 1 to clear error.
OVERRUN | A start bit is received while the previous data still lies in RXD. (Data loss). 0 (NotPresent): Error not present. 1 (Clear): Clear error on write. 1 (Present): Error present. |
PARITY | A character with bad parity is received. Only checked if HW parity control is enabled. 0 (NotPresent): Error not present. 1 (Present): Error present. 1 (Clear): Clear error on write. |
FRAMING | A valid stop bit is not detected on the serial data input after all bits in a character have been received. 0 (NotPresent): Error not present. 1 (Present): Error present. 1 (Clear): Clear error on write. |
BREAK | The serial data input is ‘0’ for longer than the length of a data frame. 0 (NotPresent): Error not present. 1 (Clear): Clear error on write. 1 (Present): Error present. |